MAXIRIS
MAXIRIS technology and envelope allow it to be installed on a wide variety of sites:
logistics sites
particularly sensitive sites: prisons, nuclear power plants, military sites, etc.
public spaces: airports, subways, etc.
industrial sites…
MAXIRIS infrared barriers further improve the performance level of SORHEA products. Indeed, for long perimeters (greater than 1km), MAXIRIS columns can be connected directly to a TCP / IP network or connected to an RS485 bus via the MAXIBUS UNIVERSAL concentrator.
The ZONING function makes it possible to create up to 3 detection zones (configurable in length) per barrier, allowing precise control of the video (alarm information per zone) and thus reinforcing the reliability of the site while maintaining a very high level security.
A multilingual HTML server integrated in each column allows all the configuration and maintenance of the system to be carried out
logistics sites
particularly sensitive sites: prisons, nuclear power plants, military sites, etc.
public spaces: airports, subways, etc.
industrial sites…
MAXIRIS infrared barriers further improve the performance level of SORHEA products. Indeed, for long perimeters (greater than 1km), MAXIRIS columns can be connected directly to a TCP / IP network or connected to an RS485 bus via the MAXIBUS UNIVERSAL concentrator.
The ZONING function makes it possible to create up to 3 detection zones (configurable in length) per barrier, allowing precise control of the video (alarm information per zone) and thus reinforcing the reliability of the site while maintaining a very high level security.
A multilingual HTML server integrated in each column allows all the configuration and maintenance of the system to be carried out
MAXIRIS | 3000 | 3100 |
Maximum interior range | 500 m | 500 m |
Column height | 1.1 m - 2 m - 2.5 m - 3 m - 3.8 m | 1 m - 2 m - 2.5 m - 3 m |
Intrusion alarm information | Up to 3 intrusion zones with distance from each configurable zone, RS 485 alarm outputs on each MAXIBUS UNIVERSAL compatible column, Ethernet (RJ45 on each column) ModBusTCP server / client compatible |
Dry Contact Outputs | 2 relays (NO) per column (configurable assignment) |
Food | 110 Vac / 230 Vac - 60 Hz / 50Hz |
Alignment assistance tools | Audible and visual signals on all columns |
Working temperature | from -35 ° to + 70 ° - Thermostatic heating in each column |
Electro-magnetic compatibility | Complies with European standards (CE label) |
Configuration tools | HTML server embedded in each column (local access) |