PAS816, PAS832

Performs all necessary functions and is suitable for the protection of detached houses or villas. This control panel is completed by functions allowing the management of a powerful siren, the disconnection of a defective backup battery, the measurement of the supply currents.
Features PAS816 PAS832
Concept of alarm system Cable modular system wired modular system
Wired zones on board 8/16 (double) 8/16 (double)
2-wire smoke detector input - -
Onboard wireless zones - -
Maximum zones in the system 32 32
Embedded PGM 3 3
Maximum PGM in the system 16 16
User + installation codes 31 + 1 31 + 1
Duress code X1, X2, X3, X4 (where X4 = X4 + 1)
Default user code Yes Yes
Keyswitch zone Yes Yes
Partitions 4 4
Sharing “Shared” (common area) Yes Yes
System timers 16 16
Maximum number of keyboards / modules in the system 15 15
Event log buffer 512 512
PSTN communicator Under construction Under construction
Integrated interface for backup communicator TTL serial TTL serial
Data bus protocol KRBUS KRBUS
Total phone numbers: CMS reports + personal numbering 4 4
Maximum number of telephone numbers for personal dialing Up to 4 Up to 4
Maximum number of phone numbers for CMS reports Up to 4 Up to 4
Reporting protocol Contact ID, 4 × 2 Contact ID, 4 × 2
Voice guide for controlling the system on PSTN PAS832 V3 only PAS832 V3 only
Voice guide for programming the system on PSTN PAS816 V3 only PAS816 V3 only
Type of detector “Roller” Yes Yes
Type of detector “Vibration” Yes Yes
Speed ​​of the “Vibration” zone (sensitivity) 0.01 - 0.25 sec. 0.01 - 0.25 sec.
Normal zone speed (sensitivity) 0.1 - 2.5 sec. 0.1 - 2.5 sec.
Zone loop type (detector) NC, NO, NF / EOL, NO / EOL, NC / DEOL, NO / DEOL, Vibration, Roll
Arming mode Absence, prolonged absence, Night, at home.
Definition of the zone Entry / exit, entry / exit, forced, interior, night interior armed, tracker, night interior tracker, perimeter, instantaneous, PGM control; 24h: burglary, silent panic, audible panic, sabotage, fire, smoke, fire button, medical button, watch fire, low water level, RF Jam, gas detected, water leaks, high temperature, low temperature
Zone attributes Activate bypass, no alarm, arm when door is closed, route of entry, exit, fire verification, alarm limitation, signaling limitation, pre- alarm, armed night
PGM attributes Reverse, heartbeat, lock, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification
Minimum AC voltage (Note: the input voltage of ~ 16 V allows the control panel to generate an output current of 0.7 A maximum) ~ 16 V ~ 16 V
Maximum AC voltage (Note: voltage over ~ 22V may damage the control panel) ~ 22 V ~ 22 V
Maximum long term control panel output current (I + AUX + I + BELL + I + PGM + battery charge): ≤1.5 A ≤1.5 A
Maximum current of slow blow fuse used in primary alternating current 250 mA 250 mA
Maximum AC power consumption 150 mA 150 mA
Minimum voltage on the outputs + AUX, + BELL, + PGM 12 V 12 V
Maximum voltage on outputs + AUX, + BELL, + PGM 13.9 V 13.9 V
Maximum current on + AUX + 1 A + 1 A
Maximum current on + BELL + 2 A + 2 A
Maximum current in -PGM - 0.05 A - 0.05 A
Maximum current on + PGM + 0.9 A + 0.9 A
Short circuit, overload protection from + BELL, + PGM, + AUX Electronic Electronic
Battery charge, + BELL, + AUX current measurement Yes Yes
Failed to disconnect backup battery (waste) Yes Yes
Maximum battery charge current + 0.4 A + 0.4 A
Maximum current of the fast blow fuse used in the battery circuit 3.15 A 3.15 A
The control panel disconnects the battery when its voltage is lower than 9.5 V 9.5 V
Recommended backup battery 12 V, 7 Ah / 20 Hr 12 V, 7 Ah / 20 Hr
Operational compliance + EN50131, Grade2 + EN50131, Grade2
Overall dimensions W x H in mm 145 x 77 145 x 77
Respect for the environment ROHS ROHS
Operating temperature - 10 ° C to 50 ° C
Production status V2 discontinued, V3 in production
Latest firmware version V2: firmw_832_v2.03b V3: firmw_832_v.3.02
Firmware upgrade in the field (by USB) PAS832 V3 only
Nominal voltage of the power supply (AC) ~ 20 V ~ 20 V